Operation Manual for TR--002Y Intellect Steam Generator



TR--002Y Intellect Steam Generator

TR--002Y Intellect Steam Generator

IMPORTANT

Please read carefully the following instructions before installing your Unit. If you have any questions on this shower installation - please call our technical support specialists Monday to Friday 9:00 am – 5:00 pm Central Time at 1-866-254-2219 Option 3 or e-mail our technical support group at sales@masterfaucet.com

Preparation

1. After opening the case, read this introduction carefully, check all the packed parts are complete by cross checking all the components against the "Diagram of unit Components". Examine for shipping damage. If the unit has been damaged or has a finishing defect, please contact Master Faucet within 2 business days. Please note that Master Faucet will not replace any damaged product or parts free of charge, ONCE the product has been installed. Master Faucet responsibility for damage in transit is limited after the unit package has been transferred to the transportation company, so you may have to contact the transportation company directly to report damage. Contact Master Faucet if you have any questions.

2. You should also consult your local building codes on questions on installation compliance standards.

TR--002Y Intellect Steam Generator

Operation Manual

The power outlet using for this steam generator must have a earthed cable and an electric shock protection, and make sure them is availability. The personnel who install this steam generator must be qualified professional.

AC Supply Voltage: 110v +,- 10%
Water Supply: 0.1-0.4Mpa

The AC supply using for steam house must be separateness, the cross-section of the power cable must exceed 2.5mm, and with a separate power switch.

Must turn off the power supply after finish using the steam generator.
Must cut off the water supply after finish using the steam generator.

A.TR-002Y Steam generator control panel
TR-002Y Steam generator control panel

B.TR-002Y Steam generator.

1.Please open the water supply valve before you push Power 'POWER' key to turn on the power. After you push Power 'POWER' key the VFD screen will be light, and the steam generator is ready for working, the window of temperature display the currently temperature.

2. Temperature setting: Push Up 'TEMPERATURE UP' key or Down 'TEMPERATURE DOWN' key on the panel, the temperature icon Temperature will flash , and predestine temperature is display. You can push Up 'TEMPERATURE UP' key or Down 'TEMPERATURE DOWN' to setting the predestine temperature. The predestine temperature limit to 20-60 C . Push the Up'Temperature UP' or Down 'TEMPERATURE DOWN' key after 3 seconds, the temperature continuously up. After set the temperature your need, the user-defined temperature be stored in computer REM automatically and the temperature window display the current temperature of bathroom. The steam generator will stop working when the temperature of bathroom is higher than or equal to the user -defined temperature for 30 seconds later, the steam generator will work again. The default temp. is 45 C .

3. Time setting:Push Up 'TIME UP' key or Down 'TIME DOWN' key on the panel, the time icon Time will display and the predestine is display , You can push Up 'TIME UP'key or Down 'TIME DOWN'key to setting the predestine time, the time step two minute for every push the time limit to:0-60 min. When the time is equal to'00' the steam generator stop working, if you need steam work continue, you must reset time again and push Steam 'STEAM'key.As if you need steam generator working without time limit, set time to'00'directly.

4. Be sure water supply is appropriate, then push Steam 'STEAM'key, the steam icon light, the steam spray out after 3 min. If water is destitute, the water destitute icon flash and the steam icon only display, Generator the steam generator stop working impermanent still the water supply is appropriate. If the water is destitute, please find out the trouble of water supply before using steam generator. On operating, you can push Steam 'STEAM'key, again to stop the steam generator working.

5. Push Fan 'FAN'key, fan icon light, the fan working, you can push Fan 'FAN'key again to stop fun working.

6. Push Top Lamp 'TOP LAMP'key, top lamp icon light, the top lamp working, you can push Top Lamp 'TOP LAMP'key again to stop top lamp working.

7. Push Back Lamp 'BACK LAMP'key, back lamp icon light, the back lamp working you can push Back Lamp 'BACK LAMP'key again to stop back lamp working.

8. Push Radio/CD 'RADIO/CD' key on the panel, radio icon light, the radio working. Push Radio/CD 'RADIO/CD' key again, radio icon light, radio working Push Radio/CD 'RADIO/CD'key again, radio icon dark,radio turn off.

On radio: (Frequency range FM87.5-108Mhz)push Tune 'TUNE'key, the radio searching broadcast, the can from 87.5Mhz to 108Mhz automatically. When get a broadcast, the radio can self-lock the broadcast, push Tune 'TUNE' key again the radio automatic search for next broadcast. As if frequency arrive 108Mhz, push Reset 'RESET' key to reset the frequency to 87.5 Mhz, then push Tune 'TUNE' key again to search broadcast automatically.

For additional information contact AquaPat Steamers at 877 789 AQUA (2782) or visit our website at www.aquapat.com or www.masterfaucet.com