TR--002Y Intellect Steam Generator
|
|
|
IMPORTANT
Please read carefully the following instructions before installing your
Unit. If you have any questions on this shower
installation - please call our technical support specialists Monday to Friday
9:00 am – 5:00 pm Central Time at
1-866-254-2219 Option 3
or e-mail our technical support group
at sales@masterfaucet.com
Preparation
1. After opening the case, read this introduction
carefully, check all the packed parts are complete by cross checking all the
components against the "Diagram of unit Components". Examine for
shipping damage. If the unit has been damaged or has a finishing defect,
please contact Master Faucet within 2 business days. Please note that
Master Faucet will not replace any
damaged product or parts free of charge, ONCE the product has been installed.
Master Faucet responsibility
for damage in transit is limited after the unit package has been transferred
to the transportation company, so you may have to contact the transportation
company directly to report damage. Contact Master Faucet if
you have any questions.
2. You
should also consult your local building codes on questions on installation
compliance standards.
TR--002Y Intellect Steam Generator
Operation Manual
The power outlet using for this steam generator must have a earthed cable and an electric shock protection, and make sure them
is availability. The personnel who install this steam generator must be qualified professional.
AC Supply Voltage: 110v +,- 10%
Water Supply: 0.1-0.4Mpa
The AC supply using for steam house must be separateness, the cross-section of the power cable must exceed 2.5mm, and
with a separate power switch.
Must turn off the power supply after finish using the steam generator.
Must cut off the water supply after finish using the steam generator.
A.TR-002Y Steam generator control panel

B.TR-002Y Steam generator.
1.Please open the water supply valve before you push
'POWER' key to turn on the power. After you push
'POWER' key the VFD screen
will be light, and the steam generator is ready for working, the window of temperature display the currently temperature.
2. Temperature setting: Push
'TEMPERATURE UP' key or
'TEMPERATURE DOWN' key on the panel, the temperature icon
will flash
, and predestine temperature is display. You can push
'TEMPERATURE UP' key or
'TEMPERATURE DOWN' to setting the predestine
temperature. The predestine temperature limit to 20-60 C . Push the
'Temperature UP' or
'TEMPERATURE DOWN' key after 3 seconds,
the temperature continuously up. After set the temperature your need, the user-defined temperature be stored in computer REM automatically
and the temperature window display the current temperature of bathroom. The steam generator will stop working when the temperature of bathroom is higher than or equal to the user -defined temperature for 30 seconds later, the steam generator will work again. The default temp.
is 45 C .
3. Time setting:Push
'TIME UP' key or
'TIME DOWN' key on the panel, the time icon
will display and the predestine is display ,
You can push
'TIME UP'key or
'TIME DOWN'key to setting the predestine time, the time step two minute for every push the
time limit to:0-60 min. When the time is equal to'00' the steam generator stop working, if you need steam work continue, you
must reset time again and push
'STEAM'key.As if you need steam generator working without time limit, set time to'00'directly.
4. Be sure water supply is appropriate, then push
'STEAM'key, the steam icon light, the steam spray out after 3 min. If water is
destitute, the water destitute icon flash and the steam icon only display,
the steam generator stop working impermanent still
the water supply is appropriate. If the water is destitute, please find out the trouble of water supply before using steam
generator. On operating, you can push
'STEAM'key, again to stop the steam generator working.
5. Push
'FAN'key, fan icon light, the fan working, you can push
'FAN'key again to stop fun working.
6. Push
'TOP LAMP'key, top lamp icon light, the top lamp working, you can push
'TOP LAMP'key again to stop top lamp working.
7. Push
'BACK LAMP'key, back lamp icon light, the back lamp working you can push
'BACK LAMP'key again to stop back lamp working.
8. Push
'RADIO/CD' key on the panel, radio icon light, the radio working. Push
'RADIO/CD' key again, radio icon light, radio working
Push
'RADIO/CD'key again, radio icon dark,radio turn off.
On radio: (Frequency range FM87.5-108Mhz)push
'TUNE'key, the radio searching broadcast, the can from 87.5Mhz to 108Mhz automatically. When get a broadcast, the radio can self-lock the broadcast, push
'TUNE' key again the radio automatic search for next
broadcast. As if frequency arrive 108Mhz, push
'RESET' key to reset the frequency to 87.5 Mhz, then push
'TUNE' key again to
search broadcast automatically.



For additional information contact AquaPat Steamers at 877 789 AQUA (2782) or visit our website at www.aquapat.com or www.masterfaucet.com

See Our Customers Kitchen & Bathroom Gallery!