Installation Manual For Steam Spa Sauna w/Massage Jets 8002-A
IMPORTANT Please read carefully the following instructions before installing your Shower Unit. If you have any questions on this shower installation - please call our technical support specialists Monday to Friday 9:00 am – 5:00 pm Central Time at 1-866-254-2219 Option 3 or e-mail our technical support group at sales@masterfaucet.comPreparation 1. After opening the case, read this introduction carefully, check all the packed parts are complete by cross checking all the components against the "Diagram of Shower Components". Examine for shipping damage. If the unit has been damaged or has a finishing defect, please contact Master Faucet within 2 business days. Please note that Master Faucet will not replace any damaged product or parts free of charge, ONCE the product has been installed. Master Faucet responsibility for damage in transit is limited after the shower package has been transferred to the transportation company, so you may have to contact the transportation company directly to report damage. Contact Master Faucet if you have any questions.2. You should also consult your local building codes on questions on installation compliance standards. 3. Install all of the required plumbing and drainage before securing the shower base. Use a competent and licensed (if required by local code) plumber for all plumbing installation.Cautions in installation and using Thank you for selecting our bathroom series. To guarantee safety and normal operation of products as well as prolong the service life, please pay attention to the following cautions: 1. After opening the case, read this introduction carefully, check all the parts, examine the shower cabin for transportation company, so you may have to contact the transportation company directly to report damage. 2. You should make sure that the floor is leveled and solid and will be able to support the total weight of the unit and its occupant. You should also consult your local building codes on question on installation compliance standards. 3. Install all of the required plumbing and drainage before securing the shower. 4. Please insure that prior to the installation the floor is leveled and the walls are at right angles. While some adjustment in leveling of the tray is possible, irregular floor level or improper angle of side walls will result in serious problems of your installation. 5. Assembled initially is not close. All screws and nuts must be screwed tightly before using. 6. The socket of steam generator shall adopt qualified product with>25A capacity. Otherwise the contact may be overheated and cause fire. 7. After using, client shall turn off power feeder switch to avoid long term energizing in the system and speeding up the aging. 8. Use clean water, if the water source is not clean enough, filtration is needed. 9. Telephone line shall not be installed in parallel with other telephone set. Additional active deconcentrator shall be installed otherwise the quality of telephone communication will be lowered or no sound can be heard. Tools Required
Notice: 1. It is unadvisable to have a shower immediately after acute sports. 2. Please avoid bath or shower in morning. 3. Keep the temperature of dressing room near to the bathroom. 4. If you feel discomfort able while having a shower, you should go out as soon as possible. 5. The time of shower is advisable to be between 15 minutes and 20 minutes, no longer. 6. Drink water to supplement moisture after shower or bathing. 7. People who suffer from heart disease, high blood pressure, diabetes or who feel unwell or pregnant woman are unadvisable to have bathing, massage or shower.
Steps of installation: First, installation of tub:
Operation ManualThe power outlet using for this steam generator must have a earthed cable and an electric shock protection, and make sure them is availability. The personnel who install this steam generator must be qualified professional. AC Supply Voltage: 110v +,- 10% The AC supply using for steam house must be separateness, the cross-section of the power cable must exceed 2.5mm, and with a separate power switch. Must turn off the power supply after finish using the steam generator. A.TR-002Y Steam generator control panel B.TR-002Y Steam generator. 1.Please open the water supply valve before you push 2. Temperature setting: Push 3. Time setting:Push 4. Be sure water supply is appropriate, then push 5. Push 6. Push 7. Push 8. Push On radio: (Frequency range FM87.5-108Mhz)push
Cleaning and maintenance 1. For routine cleaning of steam bathroom, use ordinary detergent and soft cloth. Do not use the detergent that contains acetone. In cleaning do not use the disinfectant that contains formic acid and formaldehyde. If any besmirch is left by rubber sealant wipe it gently using soft cloth with little gasoline. 2. Should any scratch be found at the surface, sandpaper it with water using 1500# waterproof abrasive paper, then apply tooth paste and polish the surface with soft cloth. 3. Remove scale instructions on the surface of frame. Wipe it using soft cloth with detergent containing light acid such as lemon juice. 4. Gilt and chrome plate needs no frequent wiping. 5. Do not use utensil of rough surface and detergent containing chemical solution or grain to wipe the frame. 6. Do not strike the frame with blunt or knife. Our product may have changes without prior notice 6For additional information contact AquaPat Showers at 877 789 AQUA (2782) or visit our website at www.aquapat.com or www.masterfaucet.com ![]() See Our Customers Kitchen & Bathroom Gallery! |












'POWER' key to turn on the power. After you push
'TEMPERATURE UP' key or
'TEMPERATURE DOWN' key on the panel, the temperature icon
will flash
, and predestine temperature is display. You can push
will display and the predestine is display ,
You can push
'STEAM'key.As if you need steam generator working without time limit, set time to'00'directly.
the steam generator stop working impermanent still
the water supply is appropriate. If the water is destitute, please find out the trouble of water supply before using steam
generator. On operating, you can push
'FAN'key, fan icon light, the fan working, you can push
'TOP LAMP'key, top lamp icon light, the top lamp working, you can push
'BACK LAMP'key, back lamp icon light, the back lamp working you can push
'RADIO/CD' key on the panel, radio icon light, the radio working. Push
'TUNE'key, the radio searching broadcast, the can from 87.5Mhz to 108Mhz automatically. When get a broadcast, the radio can self-lock the broadcast, push
'RESET' key to reset the frequency to 87.5 Mhz, then push 